Temperature Data Logger

This data logger is mainly used for temperature recording during storage and transportation of foodstuff, medicine, chemicals and other products, especially widely used in all links of warehousing, logistics and cold chain, such as refrigerated containers, refrigerated trucks, refrigerated package, cold storage, laboratory, etc.

 

Specification: 

Product size: 84mm (length) X 44mm (width) X 20 mm (height)

 

Technical parameters:

· Temperature unit:°C or °F optional

· Temperature measuring range:-30°C~ 60°C;for optional external sensor, -40°C~ 85°C;

· Ambient environmental temperature: -30°C~ 60°C;

· Accuracy: 1°C;

· Resolution:0.1°C;

· Record capacity: 16000points(MAX);

· Record interval:10s~24hour adjustable;

· Sensor: Internal NTC thermal resistor;

· Communication interface;

· Power supply: inner CR2450 battery or power supply via USB interface;

· Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.

IV. Initial use:

1. Install RC-4 temperature data logger data management software. Connect RC-4 with computer via USB, and install USB driver according to the Installation Tips.

2. Open RC-4 temperature data logger data management software, after data logger connects with PC, it will upload information automatically. After checking the information, exit from connection interface.

3. Click the parameters icon. After finish the parameters setting, click "save" button to save all the parameters and exit from parameter setting interface.

4. Hold and press the button of data logger for above 4 seconds, the symbol“ ”will light, which means recording is started, then click “upload data” to check the data.

5. Exit from RC-4 temperature data logger data management software.

V. Data access

The recorded data information could be accessed from the temperature data logger. And this process will not clear the historical memory or stop record process if it is in the record status.

1. Connect the data logger with computer via USB cable, after successfully connection, the icon shown in the LCD of data logger will light.

2. Open RC-4 temperature data logger data management software, it will automatically upload the data log by default setting of software. It could cancel “Auto upload data” in the menu of “system setting”.

  

SELLER: PYROTRON (INDIA) INC

Temperature Data Logger

Product code (MPN): ITB-09A6C5A9
Availability:In Stock
₹ 4200.00  Incl. GST ₹ 3559.32 Excl. GST
  • Description
    Temperature Data Logger

    This data logger is mainly used for temperature recording during storage and transportation of foodstuff, medicine, chemicals and other products, especially widely used in all links of warehousing, logistics and cold chain, such as refrigerated containers, refrigerated trucks, refrigerated package, cold storage, laboratory, etc.

     

    Specification: 

    Product size: 84mm (length) X 44mm (width) X 20 mm (height)

     

    Technical parameters:

    · Temperature unit:°C or °F optional

    · Temperature measuring range:-30°C~ 60°C;for optional external sensor, -40°C~ 85°C;

    · Ambient environmental temperature: -30°C~ 60°C;

    · Accuracy: 1°C;

    · Resolution:0.1°C;

    · Record capacity: 16000points(MAX);

    · Record interval:10s~24hour adjustable;

    · Sensor: Internal NTC thermal resistor;

    · Communication interface;

    · Power supply: inner CR2450 battery or power supply via USB interface;

    · Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.

    IV. Initial use:

    1. Install RC-4 temperature data logger data management software. Connect RC-4 with computer via USB, and install USB driver according to the Installation Tips.

    2. Open RC-4 temperature data logger data management software, after data logger connects with PC, it will upload information automatically. After checking the information, exit from connection interface.

    3. Click the parameters icon. After finish the parameters setting, click "save" button to save all the parameters and exit from parameter setting interface.

    4. Hold and press the button of data logger for above 4 seconds, the symbol“ ”will light, which means recording is started, then click “upload data” to check the data.

    5. Exit from RC-4 temperature data logger data management software.

    V. Data access

    The recorded data information could be accessed from the temperature data logger. And this process will not clear the historical memory or stop record process if it is in the record status.

    1. Connect the data logger with computer via USB cable, after successfully connection, the icon shown in the LCD of data logger will light.

    2. Open RC-4 temperature data logger data management software, it will automatically upload the data log by default setting of software. It could cancel “Auto upload data” in the menu of “system setting”.

      