Transformer Test Panel With Integrated Power Analyzer

₹ 165000.00  Incl. GST/Nos ₹ 139830.51 Excl. GST

Description

OPEN CIRCUIT AND FULL LOAD CURRENT - Open circuit test is carried out for measuring iron losses and full load current test is carried out for determining for total losses including iron loss.3 phase 440 volt 200 amp variac gives supply to booster transformer. Tapping of booster transformer is taken 1100 volt ,2200 volt and 3300 volt .Between variac of 200 amp and booster transformer capacitor bank of maximum 200 KVAr is inserted in the binary arrangement to maintain stability of supply and improving of power factor. Tapping of booster transformer is changed manually according to need i.e. for testing of transformer 11kv/0.43kv , 22kv/11kv and 33kv/11kv.
Application Transformer Testing
Construction Of Panel MS Steel
Rated Current 100Amps
Power 1MVA
Phase Three Phase
Ambient Temperature 50 degrees
Color Grey
Display Type Digital Meters
Frequency Range 50Hz to 100Hz

Transformer Test Panel With Integrated Power Analyzer

Product ID (MPN): ITB-84B435B6
Availability:In Stock
₹ 165000.00  Incl. GST ₹ /Nos
Brand Name Monarch Controls
Model ITB-84B435B6
Condition New
Unit Type Nos
Minimum Order Quantity 1
Minimum Ordered Packs 1
Country of Origin India
Taxes Inclusive of Tax
Ships from Bengaluru
Shipping Product eligible for free shipping
Returnable 7 Days Return
Warranty Type Manufacturer / Seller
Warranty Not Applicable
SELLER INFORMATION
Monarch Controls
Business Address
Ground Floor, M-417, Monarch Controls, 1st Stage, 8th Cross, Near TVS Cross, Peenya , Bengaluru Karnataka-560058
  • Description
    OPEN CIRCUIT AND FULL LOAD CURRENT - Open circuit test is carried out for measuring iron losses and full load current test is carried out for determining for total losses including iron loss.3 phase 440 volt 200 amp variac gives supply to booster transformer. Tapping of booster transformer is taken 1100 volt ,2200 volt and 3300 volt .Between variac of 200 amp and booster transformer capacitor bank of maximum 200 KVAr is inserted in the binary arrangement to maintain stability of supply and improving of power factor. Tapping of booster transformer is changed manually according to need i.e. for testing of transformer 11kv/0.43kv , 22kv/11kv and 33kv/11kv.
    Application Transformer Testing
    Construction Of Panel MS Steel
    Rated Current 100Amps
    Power 1MVA
    Phase Three Phase
    Ambient Temperature 50 degrees
    Color Grey
    Display Type Digital Meters
    Frequency Range 50Hz to 100Hz