Lucents Technologies India Private Limited

TTR330 3-Phase Transformer Turns Ratio Test Sets

₹ 1800000.00  Incl. GST ₹ 1525423.73 Excl. GST

Description

The TTR3XX Series of three-phase transformer turns ratio test sets is designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments.
BacklightLED
Computer InterfaceEthernet
DimensionsInstrument: 8.5 H x 21.5 W x 13 D in. (216 H x 546.1 W x 330.2 D mm)
Display Size300 mm (12 in.)
Excitation Current Range and Accuracy0 to 500 mA, 3 digit resolution, +-(2% of reading + 1 digit)
Excitation Voltage8, 40, or 80 V rms, automatically or manually selected
Input Power120V, +-10% 60Hz, +-2 Hz, 100 VA
Internal Data Storageup to 100,000 data sets
Luminance1600 nits
Measurement MethodANSI/IEEE C57.12.90
Memory32 Gigabits (SSD)
Operating Temperature23 Degree F to 122 Degree F (-5 Degree Celsius to 50 Degree Celsius)
Storage Temperature-22 Degree F to 158 Degree F (-30 Degree Celsius to 70 Degree Celsius)
Technology4-wire resistive touchscreen
Relative Humidity0 to 90% noncondensing
Accuracy+-3 minutes ( +-0.05 degrees)
Resolution1024 x 768 (VXA)
Display TypeTouchscreen display (ruggedized for field use)
  
  
SELLER: Lucents Technologies India Private Limited

TTR330 3-Phase Transformer Turns Ratio Test Sets

Product code (MPN): ITB-B2CFF313
Availability:In Stock
₹ 1800000.00  Incl. GST ₹ 1525423.73 Excl. GST
  • Description
    The TTR3XX Series of three-phase transformer turns ratio test sets is designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments.
    BacklightLED
    Computer InterfaceEthernet
    DimensionsInstrument: 8.5 H x 21.5 W x 13 D in. (216 H x 546.1 W x 330.2 D mm)
    Display Size300 mm (12 in.)
    Excitation Current Range and Accuracy0 to 500 mA, 3 digit resolution, +-(2% of reading + 1 digit)
    Excitation Voltage8, 40, or 80 V rms, automatically or manually selected
    Input Power120V, +-10% 60Hz, +-2 Hz, 100 VA
    Internal Data Storageup to 100,000 data sets
    Luminance1600 nits
    Measurement MethodANSI/IEEE C57.12.90
    Memory32 Gigabits (SSD)
    Operating Temperature23 Degree F to 122 Degree F (-5 Degree Celsius to 50 Degree Celsius)
    Storage Temperature-22 Degree F to 158 Degree F (-30 Degree Celsius to 70 Degree Celsius)
    Technology4-wire resistive touchscreen
    Relative Humidity0 to 90% noncondensing
    Accuracy+-3 minutes ( +-0.05 degrees)
    Resolution1024 x 768 (VXA)
    Display TypeTouchscreen display (ruggedized for field use)
      
      
  • FAQs