Meditech Electronics

Ventilators Drager Babylog 8000 Plus - Refurbished

₹ 400000.00  Incl. GST ₹ 338983.05 Excl. GST

Description

The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.Sensitive synchronization with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.

CONTROLS

Conventional ventilation: continuous flow, pressure limited, time-cycled
Triggered ventilation: SIMV, SIPPV, PSV1), leak adapted Trigger: Flow/volume trigger, leak adapted Trigger delay: approx. 40-60 ms
High Frequency Ventilation: CPAP+HFV, IMV+HFV Frequency: 5 to 20 Hz
Volume Guarantee Ventilation: SIMV+VG, SIPPV+VG, PSV+VG
Oxygen mixer loss (bleed flow): 0 (zero) L/min

SETTINGS

Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak inspiratory pressure: 10 to 80 mbar
PEEP/CPAP: 0 to 25 mbar
Maximal frequency: 200 bpm
Inspiratory time: 0.1 to 2 seconds » Expiratory time: 0.2 to 30 seconds
Inspiratory flow: 1 to 30 L/min
Base Flow (VIVE): 1 to 30 L/min

MONITORING

Flow monitoring: at the Y-piece, integrated
Volume monitoring: at the Y-piece, integrated
Lung function monitoring: compliance, resistance C20/C
Method: linear regression analysis
FiO2 monitoring: integrated
Real-time curves: Flow and pressure, integrated
Inspiratory oxygen concentration: 21-100 vol.% oxygen
Peak pressure: to 99 mbar
Mean airway pressure: to 99 mbar
Graphic trends: 6 parameters, integrated
Logbook: record of up to 100 alarms

SELLER: Meditech Electronics

Ventilators Drager Babylog 8000 Plus - Refurbished

Product code (MPN): ITB-8203A03E
Availability:In Stock
₹ 400000.00  Incl. GST ₹ 338983.05 Excl. GST
  • Description
    The Babylog 8000 plus is designed for harmonious ventilation of small children and the smallest pre-term babies. It has an advanced upgrade platform that has allowed it to keep pace with all new forms of treatment and clinical advances.Sensitive synchronization with gentle but precise support for spontaneous breathing reduces the work of breathing and makes the ventilation process much more comfortable for patients.

    CONTROLS

    Conventional ventilation: continuous flow, pressure limited, time-cycled
    Triggered ventilation: SIMV, SIPPV, PSV1), leak adapted Trigger: Flow/volume trigger, leak adapted Trigger delay: approx. 40-60 ms
    High Frequency Ventilation: CPAP+HFV, IMV+HFV Frequency: 5 to 20 Hz
    Volume Guarantee Ventilation: SIMV+VG, SIPPV+VG, PSV+VG
    Oxygen mixer loss (bleed flow): 0 (zero) L/min

    SETTINGS

    Inspiratory oxygen concentration: 21-100 vol.% oxygen
    Peak inspiratory pressure: 10 to 80 mbar
    PEEP/CPAP: 0 to 25 mbar
    Maximal frequency: 200 bpm
    Inspiratory time: 0.1 to 2 seconds » Expiratory time: 0.2 to 30 seconds
    Inspiratory flow: 1 to 30 L/min
    Base Flow (VIVE): 1 to 30 L/min

    MONITORING

    Flow monitoring: at the Y-piece, integrated
    Volume monitoring: at the Y-piece, integrated
    Lung function monitoring: compliance, resistance C20/C
    Method: linear regression analysis
    FiO2 monitoring: integrated
    Real-time curves: Flow and pressure, integrated
    Inspiratory oxygen concentration: 21-100 vol.% oxygen
    Peak pressure: to 99 mbar
    Mean airway pressure: to 99 mbar
    Graphic trends: 6 parameters, integrated
    Logbook: record of up to 100 alarms