HPFS Instruments India LLP

Digital Pull Off Adhesion Tester

₹ 122000.00  Incl. GST ₹ 103389.83 Excl. GST

Description

In order to perform satisfactorily, coatings must adhere to the substrates on which they are applied. There are three different adhesion test procedures to assess the resistance of paints to separate from the substrate. The cross cut test, also described as cross-hatch, uses a blade to cut through the coating to the substrate. At least two cuts are made that intersect at 90 degrees to get a right angle lattice pattern

The cross-cut area is observed for any adhesion failure. The second method to test the coating adhesion is using a stylus or loop that an increasing amount of weight is applied until the coating is removed from the substrate. The third method called pull-off adhesion, measures the amount of tensile stress to pull the coating off the substrate. A dolly is glued to the coating surface, after the glue is cured, a testing apparatus is attached to the loading fixture and aligned to apply tension perpendicular to the test surface. The force applied is gradually increased and monitored until either a plug of coating material is detached, or a specified value is reached.

BGD 500 Digital Pull-off Adhesion Tester is a portable, hand-operated instrument which is used to measure the force required to pull a specified test diameter of coating away from its substrate using hydraulic pressure. The pressure is displayed on a digital LCD and represents the coating’s strength of adhesion to the substrate.

It evaluates the adhesion (pull-off strength) of a coating by determining the greatest tensile pull-off force that it can bear before detaching. Breaking points, demonstrated by fractured surfaces, occur along the weakest plane within the system consisting of dolly, adhesive, coating layers and substrate.

Characters Convenient:

Portable design, can be used anywhere.

Built-in rechargeable lithium battery, no need any external power source.

Selectable directly four different sizes dolly for different resolution and testing range

Get the testing results from LCD directly.

Includes all tools needed for testing


Precise:

Each PsiaTester’s pressure system is calibrated to within 1% accuracy by NIST traceable load cells

High-precise professional sensor ensures 0.01MPa resolution

Self-aligning dollies ensure to get a reliable testing results for smooth or uneven surfaces.

Come with calibration certificate


Intelligent:

Store all test results includes Max. pull-off power,pull-off rate, dolly size and time automatically

Two units MPa and psi for selection and can be converted automatically.

No need any software, PsiaTester is also a U disk, when connecting the computer, operator can read all data directly which is recorded during testing.

Showing pull-off rate allows users monitor and adjust pull speed according to different test requirements.

 
Durable:

Waterproof, dustproof and shockproof design meets any harshest operating environment

Strong plastic carrying case

Two year warranty.



Accuracy +-1% Full Scale
Display Type LCD
Dolly Size 20 mm (Standard)
Model Number BGD500
Power Source Built-in rechargeable lithium battery and standard configuration charging adapter
Weight 3 Kg
Maximum Pull Force 80 MPA
Resolution 0.01 MPa (1 psi)
Dimensions 360 x 75 x 115 mm (LxWxH)
Brand Biuged

SELLER: HPFS Instruments India LLP

Digital Pull Off Adhesion Tester

Product code (MPN): ITB-1049068F
Availability:In Stock
₹ 122000.00  Incl. GST ₹ 103389.83 Excl. GST
  • Description
    In order to perform satisfactorily, coatings must adhere to the substrates on which they are applied. There are three different adhesion test procedures to assess the resistance of paints to separate from the substrate. The cross cut test, also described as cross-hatch, uses a blade to cut through the coating to the substrate. At least two cuts are made that intersect at 90 degrees to get a right angle lattice pattern

    The cross-cut area is observed for any adhesion failure. The second method to test the coating adhesion is using a stylus or loop that an increasing amount of weight is applied until the coating is removed from the substrate. The third method called pull-off adhesion, measures the amount of tensile stress to pull the coating off the substrate. A dolly is glued to the coating surface, after the glue is cured, a testing apparatus is attached to the loading fixture and aligned to apply tension perpendicular to the test surface. The force applied is gradually increased and monitored until either a plug of coating material is detached, or a specified value is reached.

    BGD 500 Digital Pull-off Adhesion Tester is a portable, hand-operated instrument which is used to measure the force required to pull a specified test diameter of coating away from its substrate using hydraulic pressure. The pressure is displayed on a digital LCD and represents the coating’s strength of adhesion to the substrate.

    It evaluates the adhesion (pull-off strength) of a coating by determining the greatest tensile pull-off force that it can bear before detaching. Breaking points, demonstrated by fractured surfaces, occur along the weakest plane within the system consisting of dolly, adhesive, coating layers and substrate.

    Characters Convenient:

    Portable design, can be used anywhere.

    Built-in rechargeable lithium battery, no need any external power source.

    Selectable directly four different sizes dolly for different resolution and testing range

    Get the testing results from LCD directly.

    Includes all tools needed for testing


    Precise:

    Each PsiaTester’s pressure system is calibrated to within 1% accuracy by NIST traceable load cells

    High-precise professional sensor ensures 0.01MPa resolution

    Self-aligning dollies ensure to get a reliable testing results for smooth or uneven surfaces.

    Come with calibration certificate


    Intelligent:

    Store all test results includes Max. pull-off power,pull-off rate, dolly size and time automatically

    Two units MPa and psi for selection and can be converted automatically.

    No need any software, PsiaTester is also a U disk, when connecting the computer, operator can read all data directly which is recorded during testing.

    Showing pull-off rate allows users monitor and adjust pull speed according to different test requirements.

     
    Durable:

    Waterproof, dustproof and shockproof design meets any harshest operating environment

    Strong plastic carrying case

    Two year warranty.



    Accuracy +-1% Full Scale
    Display Type LCD
    Dolly Size 20 mm (Standard)
    Model Number BGD500
    Power Source Built-in rechargeable lithium battery and standard configuration charging adapter
    Weight 3 Kg
    Maximum Pull Force 80 MPA
    Resolution 0.01 MPa (1 psi)
    Dimensions 360 x 75 x 115 mm (LxWxH)
    Brand Biuged

  • FAQs
    Need some help? Ask us!