Arizon Thermal Systems

Natural Gas Fired Thermic Fluid Heaters

₹ 350000.00  Incl. GST/Unit ₹ 296610.17 Excl. GST

Description

Being a customer oriented organization, we are deeply engaged in offering a wide array of Natural Gas Fired Thermic Fluid Heaters.
Capacity1,00,000 - 20,00,000 kcal/hr
BrandArizon
FuelNatural Gas
Voltage V415 V
Burner ControlYes
Voltage415 V
Temperature300 Deg C
Surface FinishingPrimer Finishing
Thermic Fluid Circulating Pump5-40 HP
I.D. Fan2-30 HP
F.D. Fan2-15 HP
PhaseThree
Fule Consumption14-274 m3/hr

Being a customer oriented organization, we are deeply engaged in offering a wide array of Natural Gas Fired Thermic Fluid Heaters.
MODELATF-100ATF-200ATF-300ATF-400ATF-600ATF-800ATF-1000ATF-1500ATF-2000
CAPACITY (kcal/hr)1,00,0002,00,0003,00,0004,00,0006,00,0008,00,00010,00,00015,00,00020,00,000
MAX. OUTLETTEMPERATURE (°C)300300300300300300300300300
FUEL COSUMPTIONNATURAL GAS (m³/hr)1428425684110140205274
THERMIC FLUID CIRCULATING PUMP5 hp7.5 hp10 hp15 hp15 hp20 hp20 hp30 hp40 hp
I.D. FAN2 hp2 hp3 hp5 hp7.5 hp10 hp10 hp20 hp30 hp
F.D. FAN (WITH COAL FIRED)-2 hp2 hp2 hp3 hp5 hp7.5 hp10 hp15 hp
CONTROLON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFF
POWER SUPPLY415 VOLTS 3-PHASE 50 Hz
 
SELLER: Arizon Thermal Systems

Natural Gas Fired Thermic Fluid Heaters

Product code (MPN): ITB-E94B7185
Availability:In Stock
₹ 350000.00  Incl. GST/Unit ₹ 296610.17 Excl. GST
  • Description
    Being a customer oriented organization, we are deeply engaged in offering a wide array of Natural Gas Fired Thermic Fluid Heaters.
    Capacity1,00,000 - 20,00,000 kcal/hr
    BrandArizon
    FuelNatural Gas
    Voltage V415 V
    Burner ControlYes
    Voltage415 V
    Temperature300 Deg C
    Surface FinishingPrimer Finishing
    Thermic Fluid Circulating Pump5-40 HP
    I.D. Fan2-30 HP
    F.D. Fan2-15 HP
    PhaseThree
    Fule Consumption14-274 m3/hr

    Being a customer oriented organization, we are deeply engaged in offering a wide array of Natural Gas Fired Thermic Fluid Heaters.
    MODELATF-100ATF-200ATF-300ATF-400ATF-600ATF-800ATF-1000ATF-1500ATF-2000
    CAPACITY (kcal/hr)1,00,0002,00,0003,00,0004,00,0006,00,0008,00,00010,00,00015,00,00020,00,000
    MAX. OUTLETTEMPERATURE (°C)300300300300300300300300300
    FUEL COSUMPTIONNATURAL GAS (m³/hr)1428425684110140205274
    THERMIC FLUID CIRCULATING PUMP5 hp7.5 hp10 hp15 hp15 hp20 hp20 hp30 hp40 hp
    I.D. FAN2 hp2 hp3 hp5 hp7.5 hp10 hp10 hp20 hp30 hp
    F.D. FAN (WITH COAL FIRED)-2 hp2 hp2 hp3 hp5 hp7.5 hp10 hp15 hp
    CONTROLON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFFON - OFF
    POWER SUPPLY415 VOLTS 3-PHASE 50 Hz
     
  • FAQs
    Need some help? Ask us!