Neutronics Manufacturing Company

Automatic Voltage Regulating

₹ 50000.00  Incl. GST ₹ 42372.88 Excl. GST

Description

Product Description Product Details : NMC''s AUTOMATIC VOLTAGE REGULATING RELAY with Digital Tap Position Indicator, TYPE : VX-4000.
 DESCRIPTION :NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.FEATURES :Ø Microcontroller based architecture with A/D Converter.Ø Password Protected.Ø Auxiliary Supply : 85V-265V AC/DCØ Linear or Inverse Time Response.Ø Relay “ON Timer”Ø Built-in Tap Position Indicator upto 40 Taps.Ø Readout of Primary / Secondary Voltages, Current & Tap No.Ø Readout of KV / KI Voltage & Current.Ø 7 segment bright red LED Displays.Ø Independent Lower, Raise & Nominal value settings.Ø Blocking for UV, OV, OC, Control Fail, Tap Fail & Min/Max Tap No.Ø Auto / Manual Mode of Operation.Ø Test Mode & Factory Reset Mode.Ø Single pulse or Continuous pulse operation.Ø Line Drop Compensator (L.D.C.).Ø Data Logging.Ø Modbus RS 485Ø RTCØ 4-20mA output from PT Voltage & TPI for SCADA.Ø PT display of 433V instead of 110V.Ø Over Current Blocking.Ø Additional C.T. for measuring the currentØ BLOCKING FOR MIN. & MAX. TAP NO.Ø Master / Slave Features.
SELLER: Neutronics Manufacturing Company

Automatic Voltage Regulating

Product code (MPN): ITB-072DD710
Availability:In Stock
₹ 50000.00  Incl. GST ₹ 42372.88 Excl. GST
  • Description
    Product Description Product Details : NMC''s AUTOMATIC VOLTAGE REGULATING RELAY with Digital Tap Position Indicator, TYPE : VX-4000.
     DESCRIPTION :NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.FEATURES :Ø Microcontroller based architecture with A/D Converter.Ø Password Protected.Ø Auxiliary Supply : 85V-265V AC/DCØ Linear or Inverse Time Response.Ø Relay “ON Timer”Ø Built-in Tap Position Indicator upto 40 Taps.Ø Readout of Primary / Secondary Voltages, Current & Tap No.Ø Readout of KV / KI Voltage & Current.Ø 7 segment bright red LED Displays.Ø Independent Lower, Raise & Nominal value settings.Ø Blocking for UV, OV, OC, Control Fail, Tap Fail & Min/Max Tap No.Ø Auto / Manual Mode of Operation.Ø Test Mode & Factory Reset Mode.Ø Single pulse or Continuous pulse operation.Ø Line Drop Compensator (L.D.C.).Ø Data Logging.Ø Modbus RS 485Ø RTCØ 4-20mA output from PT Voltage & TPI for SCADA.Ø PT display of 433V instead of 110V.Ø Over Current Blocking.Ø Additional C.T. for measuring the currentØ BLOCKING FOR MIN. & MAX. TAP NO.Ø Master / Slave Features.
  • FAQs
    Need some help? Ask us!