The Lifeline AUTO is a fully automatic defibrillator designed to analyze heart rhythm and automatically deliver a shock—without intervention—if needed. The Lifeline AUTO includes all mission critical features necessary to provide the most advanced treatment for Sudden Cardiac Arrest. Yet it’s so simple and unintimidating to use that even non-medical personnel can effectively save lives. The Lifeline AUTO was developed by experienced multidisciplinary engineering teams and incorporates state-of-the-art digital signal processing techniques and advanced ECG analysis algorithms.

Defibrillator TYPE Fully Automatic external defibrillator MODEL DDU-120A, DDU-120E WAVEFORM Biphasic Truncated Exponential (Impedance compensated) ENERGY Adult: 150 Joules Pediatric: 50 Joules (Nominal into 50 Ohm load) CHARGE TIME** DBP-2800: Less than 6 seconds DBP-1400: Less than 9 seconds VOICE PROMPTS Extensive voice prompts guide user through operation of the unit and CPR CPR PACING Metronome CONTROLS Lighted On/Off button INDICATORS · “check pads” · “do not touch patient” · “analyzing” · armed-for-shock · AED status LED **Typical, with new battery at 25° C


Patient Analysis System PATIENT ANALYSIS Automatically evaluates patient impedance for proper pad contact. Monitors signal quality and analyzes patient ECG for shockable/ non-shockable rhythms SENSITIVITY/SPECIFICITY Meets AAMI-DF-39 specifications and AHA recommendations


Self Tests AUTOMATIC Automatic daily, weekly, monthly and quarterly circuitry tests BATTERY INSERTION System integrity test on battery insertion PAD PRESENCE Pads preconnected tested daily USER-INITIATED Unit and battery pack system test may also be initiated by the user STATUS INDICATION Visual and audible indication of unit status


Defibrillation/Monitoring Pads MODEL Adult – DDP-100 Child/Infant – DDP-200P TYPE Pre-connected, single-use, non-polarized, disposable, self-adhesive electrodes with cable and connector SURFACE AREA 103 cm2 (nominal, each pad) 50 cm2 (nominal, each pad) PAD PLACEMENT Adult – Anterior/Anterior Child/Infant – Anterior/Posterior CABLE LENGTH (typical) 48 in (122 cm)

Event Documentation INTERNAL EVENT RECORD Critical ECG segments and rescue event parameters are recorded and can be downloaded to a removable data card PC-BASED EVENT REVIEW ECG with event tag display, and audio playback when available REMOVABLE STORAGE (optional) Up to 12 hours of ECG and event data storage (no audio option) or up to 2 hours of audio, ECG and event storage (audio option) on a removable data card. Actual length of storage is dependent on card capacity

Environmental TEMPERATURE Operating: 0 to 50°C (32 to 122°F) Standby (with battery installed): 0 to 50°C (32 to 122°F) RELATIVE HUMIDITY Operating / Standby: 5% – 95% (non-condensing) ALTITUDE -500 to 15,000 ft (-150 to 4500 m) per MIL-STD-810F 500.4 Procedure II VIBRATION Ground (MIL-STD-810F 514.5 Category 20) Helicopter (RTCA/DO-160D, Section 8.8.2, Cat R, Zone 2, Curve G) Jet Aircraft (RTCA/DO-160D, Section 8, Cat H, Zone 2, Curves B & R) SHOCK/DROP ABUSE TOLERANCE MIL-STD-810F 516.5 Procedure IV (1 meter, any edge, corner, or surface, in standby mode) SEALING/WATER RESISTANCE IEC60529 class IP54; Splash Proof, Dust Protected (Battery Pack installed) ESD EN 61000-4-2:2009 (open air up to 15kV or direct contact up to 8kV) EMC (Emission) EN 60601-1-2:2001 +A1:2006, limits EN 55011:1998 +A1:1999 +A2:2002 Group 1 Level B, method EMC (Immunity) EN 60601-2-4:2003, limits EN 61000-4-3:2002 Level 3 (10V/m), method


Minimum Order Quantity 1 Piece
Brand Lifeline - Defibtech
Model Name/Number DDU-120A, DDU-120E
Battery Type Lithium/Manganese Dioxide Disposable, recyclable, non-rechargeable
Type Automatic External Defibrillators
Operation Mode Automatic
Usage/Application Emergency

SELLER: Grooj Enterprises

Lifeline AUTO Fully Automatic Defibrillator

Product code (MPN): ITB-3ED86DFF
Availability:In Stock
₹ 125000.00  Incl. GST ₹ 105932.2 Excl. GST
  • Description
    The Lifeline AUTO is a fully automatic defibrillator designed to analyze heart rhythm and automatically deliver a shock—without intervention—if needed. The Lifeline AUTO includes all mission critical features necessary to provide the most advanced treatment for Sudden Cardiac Arrest. Yet it’s so simple and unintimidating to use that even non-medical personnel can effectively save lives. The Lifeline AUTO was developed by experienced multidisciplinary engineering teams and incorporates state-of-the-art digital signal processing techniques and advanced ECG analysis algorithms.

    Defibrillator TYPE Fully Automatic external defibrillator MODEL DDU-120A, DDU-120E WAVEFORM Biphasic Truncated Exponential (Impedance compensated) ENERGY Adult: 150 Joules Pediatric: 50 Joules (Nominal into 50 Ohm load) CHARGE TIME** DBP-2800: Less than 6 seconds DBP-1400: Less than 9 seconds VOICE PROMPTS Extensive voice prompts guide user through operation of the unit and CPR CPR PACING Metronome CONTROLS Lighted On/Off button INDICATORS · “check pads” · “do not touch patient” · “analyzing” · armed-for-shock · AED status LED **Typical, with new battery at 25° C


    Patient Analysis System PATIENT ANALYSIS Automatically evaluates patient impedance for proper pad contact. Monitors signal quality and analyzes patient ECG for shockable/ non-shockable rhythms SENSITIVITY/SPECIFICITY Meets AAMI-DF-39 specifications and AHA recommendations


    Self Tests AUTOMATIC Automatic daily, weekly, monthly and quarterly circuitry tests BATTERY INSERTION System integrity test on battery insertion PAD PRESENCE Pads preconnected tested daily USER-INITIATED Unit and battery pack system test may also be initiated by the user STATUS INDICATION Visual and audible indication of unit status


    Defibrillation/Monitoring Pads MODEL Adult – DDP-100 Child/Infant – DDP-200P TYPE Pre-connected, single-use, non-polarized, disposable, self-adhesive electrodes with cable and connector SURFACE AREA 103 cm2 (nominal, each pad) 50 cm2 (nominal, each pad) PAD PLACEMENT Adult – Anterior/Anterior Child/Infant – Anterior/Posterior CABLE LENGTH (typical) 48 in (122 cm)

    Event Documentation INTERNAL EVENT RECORD Critical ECG segments and rescue event parameters are recorded and can be downloaded to a removable data card PC-BASED EVENT REVIEW ECG with event tag display, and audio playback when available REMOVABLE STORAGE (optional) Up to 12 hours of ECG and event data storage (no audio option) or up to 2 hours of audio, ECG and event storage (audio option) on a removable data card. Actual length of storage is dependent on card capacity

    Environmental TEMPERATURE Operating: 0 to 50°C (32 to 122°F) Standby (with battery installed): 0 to 50°C (32 to 122°F) RELATIVE HUMIDITY Operating / Standby: 5% – 95% (non-condensing) ALTITUDE -500 to 15,000 ft (-150 to 4500 m) per MIL-STD-810F 500.4 Procedure II VIBRATION Ground (MIL-STD-810F 514.5 Category 20) Helicopter (RTCA/DO-160D, Section 8.8.2, Cat R, Zone 2, Curve G) Jet Aircraft (RTCA/DO-160D, Section 8, Cat H, Zone 2, Curves B & R) SHOCK/DROP ABUSE TOLERANCE MIL-STD-810F 516.5 Procedure IV (1 meter, any edge, corner, or surface, in standby mode) SEALING/WATER RESISTANCE IEC60529 class IP54; Splash Proof, Dust Protected (Battery Pack installed) ESD EN 61000-4-2:2009 (open air up to 15kV or direct contact up to 8kV) EMC (Emission) EN 60601-1-2:2001 +A1:2006, limits EN 55011:1998 +A1:1999 +A2:2002 Group 1 Level B, method EMC (Immunity) EN 60601-2-4:2003, limits EN 61000-4-3:2002 Level 3 (10V/m), method


    Minimum Order Quantity 1 Piece
    Brand Lifeline - Defibtech
    Model Name/Number DDU-120A, DDU-120E
    Battery Type Lithium/Manganese Dioxide Disposable, recyclable, non-rechargeable
    Type Automatic External Defibrillators
    Operation Mode Automatic