Edvantest Measure Technologies Private Limited

Rishabh Insu 20 Digital Insulation Tester

₹ 4000.00  Incl. GST ₹ 3389.83 Excl. GST

Description

Analog + Digital Display (Log scale for Insulation Measurement)The Analog scale for insulation resistance measurement is logarithmic in nature which gives the dynamic performance of an analog insulation tester.
Usage/Application Insulation Resistance Testing
Grade Automatic
Color Black
Type Of Testing Machines Insulation Resistance
Packaging Type Box
Model Name/Number Rish Insu 20
Display Type Digital
Test Voltage Upto 1000V
Range 50-100-250-500-1000
Analog + Digital Display (Log scale for Insulation Measurement)The Analog scale for insulation resistance measurement is logarithmic in nature which gives the dynamic performance of an analog insulation tester. The Analog scale is linear for low ohm and voltage measurement. User Selectable Backlit DisplayThe instrument is provided with user selectable backlit for taking measurements in dark areas/poor lighting conditions. Connector jack for External Mains Adapter (Optional)The instrument can be operated from mains supply (230V AC) instead of batteries using an external mains adapter (230V AC/9V DC, 500mA (4.5VA) isolated) Test Voltages 50V/100V/250V/500V/1000VTest voltages from 50V to 1000V can be selected for insulation resistance measurement. It covers all insulation tests up to 1000V. Insulation Resistance MeasurementThe instrument is capable of measuring insulation resistance from10kOhm…2GOhm. Low Resistances Measurement (0.01Ohm... 99.9 Ohm)Low resistances can be measured up to 99.9Ohm. There are two measuring ranges for Low Ohm : 9.99Ohm and 99.9Ohm. Hands-free continuity testingContinuity testing (0-10Ohm with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated. VoltmeterInstrument measures voltages >25V … 600V AC/DC Automatic discharge for capacitive circuits after test measurementCapacitive devices under test, such as cables and windings that get charged during the test are discharged by the tester. Live circuit detectionDisplays presence of voltages >25V irrespective of function selected. Blown fuse indicationThe display FUSE points to a blown fuse. Pre-selectable measurement time for Insulation Resistance MeasurementIn normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released. With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 min. Pre-selectable limit checks (Go/ No-go option) for MOhm / GOhmAn acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value. Lead resistance null facilityThe instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances. Storage of MIN / MAX valuesIn addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored. Storage Memory for last 10 readingsThe instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, continuity and resistance measurement. Stop WatchThis function allows you to measure elapsed time up to 1 hour. Auto-power off functionThe instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation. Protective holster for rough dutyA holster of soft rubber with tilt stand protects the meter against damage in case of shock and drop.

SELLER: Edvantest Measure Technologies Private Limited

Rishabh Insu 20 Digital Insulation Tester

Product code (MPN): ITB-880C6C2C
Availability:In Stock
₹ 4000.00  Incl. GST ₹ 3389.83 Excl. GST
  • Description
    Analog + Digital Display (Log scale for Insulation Measurement)The Analog scale for insulation resistance measurement is logarithmic in nature which gives the dynamic performance of an analog insulation tester.
    Usage/Application Insulation Resistance Testing
    Grade Automatic
    Color Black
    Type Of Testing Machines Insulation Resistance
    Packaging Type Box
    Model Name/Number Rish Insu 20
    Display Type Digital
    Test Voltage Upto 1000V
    Range 50-100-250-500-1000
    Analog + Digital Display (Log scale for Insulation Measurement)The Analog scale for insulation resistance measurement is logarithmic in nature which gives the dynamic performance of an analog insulation tester. The Analog scale is linear for low ohm and voltage measurement. User Selectable Backlit DisplayThe instrument is provided with user selectable backlit for taking measurements in dark areas/poor lighting conditions. Connector jack for External Mains Adapter (Optional)The instrument can be operated from mains supply (230V AC) instead of batteries using an external mains adapter (230V AC/9V DC, 500mA (4.5VA) isolated) Test Voltages 50V/100V/250V/500V/1000VTest voltages from 50V to 1000V can be selected for insulation resistance measurement. It covers all insulation tests up to 1000V. Insulation Resistance MeasurementThe instrument is capable of measuring insulation resistance from10kOhm…2GOhm. Low Resistances Measurement (0.01Ohm... 99.9 Ohm)Low resistances can be measured up to 99.9Ohm. There are two measuring ranges for Low Ohm : 9.99Ohm and 99.9Ohm. Hands-free continuity testingContinuity testing (0-10Ohm with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated. VoltmeterInstrument measures voltages >25V … 600V AC/DC Automatic discharge for capacitive circuits after test measurementCapacitive devices under test, such as cables and windings that get charged during the test are discharged by the tester. Live circuit detectionDisplays presence of voltages >25V irrespective of function selected. Blown fuse indicationThe display FUSE points to a blown fuse. Pre-selectable measurement time for Insulation Resistance MeasurementIn normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released. With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 min. Pre-selectable limit checks (Go/ No-go option) for MOhm / GOhmAn acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value. Lead resistance null facilityThe instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances. Storage of MIN / MAX valuesIn addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored. Storage Memory for last 10 readingsThe instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, continuity and resistance measurement. Stop WatchThis function allows you to measure elapsed time up to 1 hour. Auto-power off functionThe instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation. Protective holster for rough dutyA holster of soft rubber with tilt stand protects the meter against damage in case of shock and drop.

  • FAQs
    Need some help? Ask us!